Kysy lisätietoja tuotteesta
  1. Name(*)
    Pakollinen tieto!
  2. Company
    Invalid Input
  3. Phone
    Pakollinen tieto!
  4. Email(*)
    Pakollinen tieto!
  5. Message(*)
    Pakollinen tieto!
« Back to product listing
Logo Array

S301 Dust Monitor

On/Off Switch for filter leak detection

With two independent alarm relays, Sintrol's S301 allows the end user to identify bag leaks and deterioration of filters.  Using our electric induction measurement principle, the dust monitor can be easily set up within 30 minutes of installation and gives plant operators quick notification of breaches in the filtration system.

Sintrol dust monitor allows end users to manually adjust alert and alarm level signals to tailor to their end needs.  Different probe lengths and coatings give flexibility to meet a variety of applications.

S300 Series dust monitors

Measurement Objects

Solid particles in gas flow

Particle Size

0.3 µm or larger

Measurement Range

From 0.1 mg/m³ 

Measurement Principle

Inductive Electrification

Protection Category

IP65

Probe Length (total/measuring)

500mm/440mm, 750mm/690mm (optional),1000mm/940mm (optional), others on request

19.7" / 17.3", 29.5" / 27.2", 39.4" / 37.0" (optional), others on request

Power Supply

115 VAC, 230 VAC or 24 VDC

Power Consumption

DC model Max 3 W, AC model Max 8 W

Wiring Connections - Power Supply

DIN PG11 cable gland

Wiring Connections - Output Signals

DIN PG11 cable gland

Process Connection

Socket (38 mm OD), quick clamp (optional), flange (optional)

Output Signals

- Two SPDT relays: 5A, 24V AC/DC

Communication Interface

Serial Communication RS-485

Range Set Up

- Normal measuring range: automatic, based on average measured dust flow during setup procedure
- Extended measuring range: User selectable

Relay Alarm Settings

- Automatic, set at factory: Based on average measured dust flow
- User selectable ranges

Offset Trim

Automatic drift compensation

Signal Damping Time

0 - 300 s

Relay Delay Time

0 - 180 s

Process Conditions

Temperature
Max 300°C, Max 700°C (optional)
Max 572 °F, Max 1292 °F (optional)

Pressure

Max 200 kPa, Max 600 kPa (optional)
Max 43.5 PSI, Max 87 PSI (optional)

Gas Velocity

Min 4m/s  ı  Min 13.1 ft/s

Humidity

Max 95% RH (non-condensing)

Ambient Conditions

Temperature

-20 to +45°C and to 60°C for 24 VDC

-4 to 113 °F and to 140 °F for 24 VDC

Humidity

Max 95% RH (non-condensing)

Vibration

Max 5 m/s²  ı  Max 16.4 ft/s2

Materials

Probe (wetted part)

Stainless steel (AISI 316L)

Probe Coating (wetted part)

PTFE Teflon (optional)

Process Connection (wetted part)

Stainless steel (AISI 316L)

Probe Insulation  (wetted part)

PEEK

Probe Sealing (wetted part)

FPM Viton

Enclosure

Aluminum alloy

Weight

2.3kg  ı  5.1 lbs

CLOSER DETAILS AS PDF-FILES